The Daily Air Brake Check, Step By Step
Eight checks in the order the handbook gives them, and the number each one should hit.
By Alan Bradshaw (author page). Sources read November 21, 2026.
The handbook's air brake check runs in a set order. Each step catches a different failure. Here it is in plain words, with the number to watch at each step.
| Step | What You Do | What Good Looks Like |
|---|---|---|
| Build up rate | Engine at operating rpm, watch the gauge climb | 85 to 100 psi within 45 seconds on a dual air system |
| Governor cut out | Keep building until the compressor stops | Usually about 120 to 140 psi, or the maker's number |
| Governor cut in | Pump the pedal to bleed air down | Compressor starts again around 100 psi |
| Leakage, released | Engine off, parking brake in | Under 2 psi a minute single, under 3 combination |
| Leakage, applied | Engine off, foot brake held one minute | No more than 3 psi single, 4 combination |
| Low air warning | Fan the pedal to drop pressure | Light and buzzer on before the gauge reads 55 psi |
| Spring brakes | Keep fanning | Parking brake knob pops out, usually 20 to 45 psi |
| Parking brake | Set it and gently pull against it in a low gear | The truck does not move |
All numbers from Section 5 of the Texas DPS CDL handbook (DL-7C). Older single air systems from before 1975 use a slower build up target of 50 to 90 psi within 3 minutes at idle.
Why The Order Matters
The leak test needs a full tank, so the governor check comes first. The warning and spring brake checks drain the tank on purpose, so they come last. Do them out of order and you will be building air twice.
Drain The Tanks
Compressed air carries water and some compressor oil into the tanks. The handbook tells drivers to drain them, fully, at the end of each day if there is no automatic drain. Water in the system can freeze in cold weather and stop the brakes from working. In South Texas a freeze is rare, but the water and oil still collect in the bottom of the tank, so drain it completely.
When A Step Fails
Slow build up points at the compressor, its belt or a leak big enough to keep up with it. A governor that never cuts out can over fill the system. A warning that comes on late means you could lose air without knowing. Each of these is a reason to stop and fix the truck before it moves. Use the leak test calculator on your numbers, or read what to do when the light comes on while driving.